You are here: Home > Products > Pack-Away Doors > Technical Data
|
|
Pack-Away Doors
Technical Data
All the structure of pack-away door is self-bearing.
- Upper Framework ................
|
in zinc-plated steel or, on request, in stainless steel INOX 304.
|
- Guard ...................................
|
for motor and rolling shaft protection in zinc-plated steel or, in stainless steel INOX 304 as an optional.
|
- Guides ..................................
|
in zinc-plated steel or, upon request, in stainless steel INOX 304.
They are equipped with pvc anti-crash profiles or, on request, with nylon brushes.
|
- Curtain .................................
|
made in pvc coated poliester, 680 gr/sqm, flame retardency cl. 2.
Another versions available: pvc coated poliester 900 gr/sqm, flame retardency cl. 2, or insulated type 4 mm thick.
It is possible to manufacture curtain with many transparent sections, completely coloured one or personalized with our Customers' logo.
|
- Lift Shaft ...............................
|
in zinc-plated steel or, in stainless steel INOX 304 if requested.
|
- Cross Bars ............................
|
either in zinc-plated steel or, in stainless steel INOX 304.
|
- Lifting Belts ..........................
|
at high traction resistance.
|
- Safety Devices ......................
|
to european regulations in force (photocells, safety edge, blinker).
|
- Opening Devices ...................
|
in case of power failure: handle on the motor unit or, at Customers' request, counter-weight system.
|
It can be painted with any RAL colour.
Flexible Curtain
Main details:
- Fabric made of polyester covered with PVC.
- Flame retardant cl. 2.
- Fabric strength: abt. 3.000 N/5 cm. in warp and weft.
- Tear strength: abt. 400 N in warp and weft.
- Total weight: standard version: 680 gr./sqm. As an option: 900 gr./sqm., 1700 gr./sqm.
- Thickness: standard version: 0,8 mm. As an option: insulated version: 4 mm.
- Wind resistant cross-bars made of zinc-plated steel incorporated into flexible panel.
- Lifting belts made of polyester, flame retardant cl.1.
Standard version: two transparent portholes (at the high of a person and at the high of a forklift truck).
It is possible to put more transparent portholes in the panel or to manufacture a completely stained panel.
Structure
Upper framework and lateral runners: standard version is made of zinc-plated steel. As an option we can propose you a version made of painted steel or of stainless steel INOX 304.
Upper framework and lateral runners thickness: 2 mm.
Rise shaft, reduction gear, rotating cam limit switch and rolling-up shaft are installed on the upper framework. The anti-collision (push) profiles are put into the lateral runners.
Lift Shaft
Lift shaft is made of steel.
Motor
The asynchronous three-phase electric motors of Bonfiglioli - Riduttori Motovario's production range, are available in basic designs IMB5 and IMB14 and derived versions.
Sizes in the range of IEC 63-160 with powers in the field 0.12-15 kW are available (4 pole - 1500 min - 1 - S1).
Our motors are supplied standard with IP 54 protection class (for brake motors) to CEI standards 2-16/IEC 34-5.
They are cooled by external ventilation (IC 411 to CEI 2-7/IEC 34-6) and are equipped with a radial fan in plastic working in both directions.
The motor is suitable for heavy duty (1550 rpm).
The reduction gear is lubricated.
The S factor is:
- 0,37 Kw -> S = 2
- 0,75 Kw -> S = 3
- 1,5 Kw -> S = 1,7
Plastic electric box with electric cables (insulation 450/750V CEI 20-22).
Italian Standards
| Title |
CEI |
IEC |
| General requirements for rotating electrical machines |
CEI 2 - 3 |
IEC 34 - 1 / 83 |
| Terminal markings and direction of rotation of rotating machines |
CEI 2 - 8 |
IEC 34 - 8 |
| Methods of cooling for electrical machines |
CEI 2 - 7 |
IEC 34 - 6 |
| Dimensions and output ratings for rotating electrical machines |
UNEL 13113 - 71
UNEL 13117 - 71
UNEL 13118 - 71
|
IEC 72 |
| Classification of deegree of protection provided by enclosures for rotating machines |
CEI 2 - 16 |
IEC 34 - 5 |
| Noise limits |
CEI 2 - 24 |
IEC 34 - 9 |
| Classification of type of construction and mounting arrangements |
CEI 2 - 14 |
IEC 34 - 7 |
| Rated voltage for low voltage mains power |
CEI 18 - 6 |
IEC 38 |
| Vibration level of electric machines |
CEI 2 - 23 |
IEC 34 - 14 |
Foreign Standards
| Nation |
Standard |
| Australia |
AS 1359 |
| Austria |
OEVE M 10 |
| Belgio |
NBNC 51 - 101 |
| Canada |
CSA C22.2 N° 100 |
| Francia |
NF C 51 |
| Germania |
DIN VDE 0530 |
| Gran Bretagna |
BS5000 / BS4999 |
| Norvegia |
NEK IEC 34 |
| Olanda |
NEN 3173 |
| Svezia |
SS 426 01 01 |
| Svizzera |
SEV 3009 |
Standard industrial voltage: 220 / 400 Vac - 50 Hz
Options
Other possibilities we can propose:
| Industrial Voltage |
Frequency |
| 240 / 415 Vac |
50 Hz |
| 260 / 440 Vac |
60 Hz |
| 280 / 480 Vac |
60 Hz |
The power is proportional to the door dimensions:
- 0,37 Kw (0,5 HP)
- 0,75 Kw (1,0 HP)
- 1,5 Kw (2,0 HP)
- 2,2 Kw (3,0 HP)
- 3,0 Kw (4,0 HP)
Brakes
- Electro-magnet containing the toroidal coil, secured with three screws on the rear shield fan side; three preloaded springs ensure axial positioning.
- Mobile armature plate preset for dust protection elements assembly.
- Axially independent brake disk connected to the shaft by the trailinghub.
- Braking springs.
|
|
|
 |