HIGH SPEED
PACK AWAY DOORS - TECHNICAL DETAILS
- Flexible
panel
Fabric
made of polyester covered with pvc
Flame
retardant cl. 2
Fabric
strength: abt. 3.000 N/5 cm. in warp and weft
Tear
strength: abt. 400 N in warp and weft
Total
weight: standard version: 680 gr./sqm. As an option: 900 gr./sqm., 1700
gr./sqm.
Thickness:
standard version: 0,8 mm. As an option: insulated version: 4 mm.
Wind
resistant cross-bars made of zinc-plated steel incorporated into
flexible panel
Standard
version: two transparent portholes (at the high of a person and at the
high of a forklift truck). It is possible to put more transparent
portholes in the panel or to manufacture a completely stained
panel.
Lifting
belts made of polyester, flame retardant cl.1
Manufacturing
of our pvc flexible panels:
- Free-standing
framework
Upper
framework and lateral runners: standard version is made of zinc-plated
steel. As an option we can propose you a version made of painted steel
or of stainless steel INOX 304.
Upper
framework and lateral runners thickness: 2 mm.
Rise
shaft, reduction gear, rotating cam limit switch and rolling-up shaft
are installed on the upper framework. The anti-collision (push)
profiles are put into the lateral runners.
3. Rise
shaft
Rise shaft
is made of steel.
4. Motor
The
asynchronous three-phase electric motors of Bonfiglioli-STM
Riduttori Motovario's production
range, are available in basic designs IMB5 and IMB14 and derived
versions. Sizes in the range of IEC 63-160 with powers in the field
0.12-15 kW are available (4 pole - 1500 min -1 -S1). Our motors are
supplied standard with IP 54 protection class (for brake motors) to CEI
standards 2-16/IEC 34-5. They are cooled by external ventilation (IC
411 to CEI 2-7/IEC 34-6) and are equipped with a radial fan in plastic
working in both directions.
STANDARDS
|
TITLE
|
CEI
|
IEC
|
|
General
requirements for rotating electrical machines
|
CEI 2
- 3
|
IEC 34
-
1/83
|
|
Terminal
markings and direction of rotation of rotating machines
|
CEI 2
- 8
|
IEC 34
- 8
|
|
Methods
of
cooling for electrical machines
|
CEI 2
- 7
|
IEC 34
- 6
|
|
Dimensions
and output ratings for rotating electrical machines
|
UNEL
13113
- 71
13117
- 71
13118
- 71
|
IEC 72
|
|
Classification
of deegree of protection provided by enclosures for rotating
machines
|
CEI 2
- 16
|
IEC 34
- 5
|
|
Noise
limits
|
CEI 2
- 24
|
IEC 34
- 9
|
|
Classification
of type of construction and mounting arrangements
|
CEI 2
- 14
|
IEC 34
- 7
|
|
Rated
voltage for low voltage mains power
|
CEI 18
- 6
|
IEC 38
|
|
Vibration
level of electric machines
|
CEI 2
- 23
|
IEC 34
- 14
|
FOREIGN
STANDARDS
|
DIN
VDE
0530
|
GERMANY
|
|
BS5000
/
BS4999
|
GREAT
BRITAIN
|
|
AS 1359
|
AUSTRALIA
|
|
CSA
C22.2
N° 100
|
CANADA
|
|
NBNC
51 -
101
|
BELGIUM
|
|
NEK
IEC 34
|
NORWAY
|
|
NF C 51
|
FRANCE
|
|
OEVE M
10
|
AUSTRIA
|
|
SEV
3009
|
SWITZERLAND
|
|
NEN
3173
|
NETHERLANDS
|
|
SS 426
01
01
|
SWEDEN
|
Standard
industrial voltage: 220/400 Vac 50 Hz
Other
possibilities we can propose:
|
INDUSTRIAL
VOLTAGE
|
FREQUENCY
|
|
240/415 Vac
|
50
Hz
|
|
260/440 Vac
|
60 Hz
|
|
280/480 Vac
|
60 Hz
|
The power
is proportional to the door dimensions (0,37- 0,75 -1,5-2,2 Kw = 05-
1-2-3 Hp).
The motor
is suitable for heavy duty (1400 turns).
The
reduction gear is lubricated. The S factor (0,37 kw S=2, 0,75 kw S=3 ,
1,5 kw S=1,7).
Rotating
cam limit switch for setting of the door opening and closing, IP 55
protection class (to CEI 44.5 / 729 CEI 17.13).
Plastic electric box
with electric
cables (insulation 450/750V CEI
20-22).
5. Brake
- Electro-magnet
containing the toroidal coil, secured with three screws on the rear
shield fan side; three preloaded springs ensure axial
positioning.
- Mobile
armature plate preset for dust protection elements assembly.
- Axially
independent brake disk connected to the shaft by the
trailinghub.
- Braking
springs.
|